XM-F52-8C X-RAY

XM-F52-8C X-RAY
Product Detailed
Related Categories:Ultrasonic
XM-F52-8C X-RAY
GeneratorRadiography kV Range44 to 125kV total 41 steps
Radiography mA Range30 to 500mA total 8 steps
Exposure Time0.02 to 5s total 23 steps
Fluoroscopy kV Range44 to 110kV
Fluoroscopy mA Range0.5 to 5mA continuous regulation
TOMOTomographic capability
Anatomical ProgramingYes
Power Supply380VAC±38VAC, 3-phase
Power Frequency50/60Hz±1Hz
Power Capacity
50kVA
X-ray Tube XD52-30.50/125                       XD51-20.40/125
Rated Voltage125kV                                   125kV
Rated Focal Spot Value1.0/2.0mm                             1.0/2.0mm
Max Power(0.ls)(kW)30 (small) / 50 (big)                 20 (small) / 40 (big)
Rotate Speed (min1/rpm)2800 (50Hz)                           2800 (50Hz)
Anode Heat Storage Capacity190,000HU                             140,000HU
Heat Storage of Tube Assembly1,250,000HU                           1,250,000HU
Diagnostic TableFilm Size and Exposure Procedure8" × 10"             
10" × 12"           
11" × 14"           
14" × 14"
Send Film MethodFilm feed driven by motor; Automatic skipping
Range of Movement≥720mm ( longitudinally )
≥200mm ( transversely )
≥260mm for pressure direction, Press power:       80~100N
Pattern of MovementDriven electrically
Filtering GridFixed type; grid ratio: r=8; grid density: N=40L/cm
Focal distance: 70cm; Size: 14" ×14"
Range of Movement+90° ~ 0° ~ -15°
Pattern of MovementDriven electrically, at a speed of about 90°/30s
Range of MovementAble to be extended 30cm at the front end
Pattern of MovementDriven electrically, at a speed of about 3cm/s
Radiographic TableTabletop Length2000mm
Tabletop Width740mm
Tabletop Height658mm
Tabletop MovementLongitudinal: 1200mm; Lateral: 200mm
Strut Movement Along Table (Longitudinal)1200mm
DIS Travel while X-ray Tube Assembly Vertically Moving up and down1100mm
Rotation Range of X-ray Tube Around Lateral Arm+120° ~ -120°
Strut Rotation Range+180° ~ -180°
Tabletop Lockingelectromagnetically locking, brake pressure≥100N
Tabletop Locking Controlfootswitch (normally closed)
Bucky Vibration ModeFixed type
Focusfo=100
Grid Size14" X 17" ( 356mm × 432mm )
Film Loaded in BuckyMax 14" × 17"
Longitudinal Travel of Bucky500mm
Bucky Lockingelectromagnetically locking, brake pressure≥100N
Image SystemWorking ModeContinuous
Scanning Ratio2.1 Interlaced
Number of Scanning Line625TCL
Number of Frame per Second       25
Aspect Ratio4: 3
CCD Camera400,000 pixels CCD
ResolutionHorizontal Center≥800 TVL; Vertical Center≥400 TVL
Image IntensifierModelThales
Input size9 inch (9”/6”/4.5”)
Resolution46 lp/cm
DQE65%
Image Processing Function
Last image hold
8 images storage
Dynamic function
Static function
Digital mask circle
Automatic KV control
14 inch monitor 1set
Collimator 
XS1-2                                   XS1-2 
Mode of AdjustmentManuel                                 Electrically-Driven
Maximum Tube Voltage150kV                                   150kV
Radiation Field [Max SID = 65cm] 350mm X 350mm                   350mm X 350mm
Radiation Field [Min SID = 100cm]0                                           ≤50mm X 50mm
Time Limit of the Light Source≤60s                                     N/A
Inherent Filtration1.5 (mmAl)                             N/A
External Dimension (L×W×H)250×224×250mm                   212×212×223mm

XM-F52-8C X-RAY